Publishing Entity: TES ELECTRICAL & MECHANICAL LIMITED
Company Registration Number: SC447561 (Scotland)
Registered Address: 5 Hornock Road, Coatbridge, ML5 2QA, Scotland, United Kingdom
Director: Ais Ais
Effective Date: Last updated 2026 (Operational since 15 April 2013)
1. Educational & Informational Scope Only
All content available on this portal – including without limitation technical articles, engineering handbooks, calculation tools (such as the interactive BS 7671 Cable Sizing & Voltage Drop Calculator), component monographs, and testing checklists – is published solely for general informational and educational reference.
Nothing on this website constitutes formal engineering design certification, statutory building warrant approval, or site-specific electrical installation commissioning. Site conditions, ambient temperatures, cable grouping factors, soil thermal resistivity, and supply transformer impedances vary substantially across projects and require empirical verification.
2. Requirement for Qualified & Certified Personnel
Physical electrical and mechanical installation work in the United Kingdom involves inherent risks of electric shock, arc flash, burn injury, and fire. Under the Electricity at Work Regulations 1989 (EAWR), all electrical systems must be constructed, maintained, and verified by competent persons possessing adequate technical knowledge and experience.
Readers, contractors, and building owners must not attempt to modify high-voltage or low-voltage electrical systems without holding accredited qualifications (such as City & Guilds 2382/2391 or Scottish equivalent SELECT/NICEIC certifications) and utilizing calibrated test instruments conforming to BS EN 61557.
3. Algorithmic Tools & Calculation Disclaimers
While our interactive calculation algorithms are constructed based on published mathematical models from BS 7671:2018+A2:2022 (Table 4D1A, Table 4D2A, Appendix 4), calculations are indicative only. Real-world conductor thermal withstand, adiabatic equation checks (k²S² ≥ I²t), and fault loop impedance limits must always be verified by an accredited electrical engineer on a project-specific basis.
4. Emergency & Life Safety Protocols
If you detect smoke, electrical arcing, burning odours, or insulation failure, do not consult online resources:
- Immediately isolate the electrical supply at the main incomer switch if safe to do so.
- Evacuate the immediate area and dial 999 for emergency fire and rescue services.
- For hazardous distribution network faults or overhead line failures in Scotland, dial 105 to contact your local Distribution Network Operator (SP Energy Networks).
5. Limitation of Liability
To the maximum extent permitted under Scots Law and UK legislation, TES ELECTRICAL & MECHANICAL LIMITED, its director Ais Ais, and technical contributors disclaim all liability for any direct, indirect, consequential, or incidental loss or damage arising from reliance on the informational resources or tools provided on this portal.
Contact for Technical Queries: TES ELECTRICAL & MECHANICAL LIMITED, 5 Hornock Road, Coatbridge, ML5 2QA, Scotland, United Kingdom • Telephone: +44 1236 439281 • Email: [email protected]